Raised Flooring Of Computer Rooms

raised flooring of computer roomsThe raised flooring of computer rooms means elevated flooring on a concrete, marble or any other type of flooring.  It is termed as computer floor, server room flooring or raised access floor. The floor covering constitutes of elevated access floor panes made out of steel sheets and soldered construction filled with lightweight cement or wood. The size of floor panels in metric size comes to US Imperial size of 24″ x 24″ or 600 x 600 mm in general. They are further supported by modifiable support pedestals underneath. The space between the elevated flooring and the regular flooring offers you ample space to run services like telecom, data, electricity, air conditioning duct, security, suppression, environmental control etcetera. The panels of the flooring can be removed effortlessly to access to the systems and devices underneath floor.

Wood core elevated access floors are one of the most popular pick for most of the people. Its surfaces are covered with HPL tiles or PVC, making it resistant to any kind of wear and tear. If you are looking for resistant flooring then you should go for carpet covered RA flooring in place of wood core elevated floors.  Perforated raised floors are also a good choice if you need ventilated flooring.

Benefits of Raised floor access.

Cooling: The temperature inside the computer room is usually higher than the rest of the rooms. It is essential to maintain a favorable temperature inside the room for the proper functioning   of computers, servers and other related peripherals. The floor has distinctive cooling capabilities to bring down the temperature of the room at an optimum level. The floor offers adequate space to circulate the conditioned air underneath the equipments.  Tiles and diffuser ducts are systematically laid under the flooring to boost up the circulation of conditioned air. It has a remarkable cooling effect.

Fire Suppression: Almost all the data of companies, even personals are stored in data centers nowadays. It is indispensable and extremely valuable. The data centers need an enormous amount of power to operate. It even includes a number of high density cables, wires and circuits hence the danger of fire is perpetually high. Looking at the usefulness of the stored data and investment on servers depending on smoke detectors, fire extinguisher and sprinkler heads is not ample. The flooring of computer and server rooms aids in firefighting as they are made from fireproof material. It acts as a barrier between peripherals and cables laid below. Installing automatic fire shutoff is an effective option to prevent fire spreading.

Flexibility: The flooring includes removable panes, it offer adaptability and flexibility. The tiles are extremely lightweight and easily interchangeable. They can be taken out to install cables or undertake repairs. It is tremendously useful feature as new devices are constantly needed to be added. It also offers you the liberty of modifying the layout without hampering the operational activity.

Profession Look: They provide a modern, elegant and professional look. They hide most of the cables and cords that generally lay cluttered in the data-center. Easy to clean and maintain these floorings are must for every computer lab and server room area.

For More Information Visit Here:- Mantara Construction

Undertaking Computer Room Flooring

raised flooring of computer roomsComputer room flooring is essential for server and computer rooms. It has elevated flooring on the concrete floor that is the reason it is also known as raised floor. It provides adequate space for air conditioning and power need of the server room. The construction of the elevated floor is a tough task. It needs lots of time, effort and proper planning. Looking at the benefits it is worth putting the time and efforts.

It is essential to assemble all the components in a way that it allows flow of air without causing any hindrance to the working of equipment. There are two things you should consider before starting with Raised Floor work, the first is the area of the computer room and second is budget. Once you have carefully evaluated these two aspects then you start with the construction.

It is good to hire experienced and skilled graphic designer as there are a lot of technicalities and calculation needed like deciding the alleviation of raised floor or spot for the devices. The designers use Computational Fluid Analysis to decide the location below and above the flooring. They will help you decide the appropriate place for putting up punctured ceramic tiles and computer equipment that will be placed after sometime. All these points are essential to be taken into consideration since technological advancement needs replacement of existing equipment along with the addition of new ones.

Various kinds of appliances are used to eliminate any obstruction in the flow of air over as well as under the floor.  The central portion of the server/computer room should be utilized for keeping equipment that are combatively large and are needed on a moderate or minimal basis. The preference of the application mainly depends on the equipment being used. Once everything is finalized, the Hot & Cold Church aisle setup is completed, around the central part of the flooring fresh air is distributed via perforated flooring. The heat generated by the various server room equipments can be directed towards equipment needing high temperature. Some of the items in the server room need to be placed as low solidity area as they need constant cooling down all through the elevation floor options while others need chilling through high cooling solution like cupboard air conditioning. Mainly there are two types of flooring that you are will generally come across in the computer room.

Earlier Middle Elevated Flooring was tremendously popular. In this, floor is first split than a sub-floor is created. It serves as an effective discharge medium for eliminating feasible air leaks originating from the gadgets. The cooled water pipes are placed on the subfloor for providing chilling solution.  In this data cables are systemically placed over the new raised floor. The ceiling size is of the area is over 9 feet. The devices need to be placed at a minimum 19 inch away from the ceiling.   The computer or server rooms with Data Center Elevated Floorings have comparatively more height than the Information Middle Elevated flooring. They even act as an effective barricade by prohibiting the entry of water in the area.

For More Information Visit Here:- Mantara Construction